SL 5 Rinar - Precise remote methane detection for safe network monitoring

 

GasMessgeraet-4000The SL 5 Rinar is an innovative remote detection laser measuring device for safe and efficient gas monitoring in the supply network. Developed to meet the high demands of technical specialists at network operators, the device enables precise monitoring of pipelines and inaccessible house connections.

Reliable remote detection of methane


The SL 5 Rinar can be used to reliably check exposed pipes and house connections in accordance with DVGW G 465-4-6 from distances of up to 50 meters. The laser detects methane exclusively, offering maximum measurement reliability without cross-sensitivity to other hydrocarbons. The device is ideal for regular inspection of industrial pipe networks, plant areas, and sections that are difficult to access.

Convenient operation and robust design

The color LCD display provides a clear visualization of the measurement results. The adjustable alarm threshold allows for individual adaptation to different operating conditions. Precise target alignment is ensured thanks to the switchable red marking laser and the integrated target sight. The metal housing guarantees durability even under harsh operating conditions.

 

Technical highlights

  • Selective methane measurement – no cross-sensitivity
  • Measuring range up to 50 m
  • Color LCD with reflection quality display
  • Adjustable alarm threshold
  • Robust metal housing
  • Easy one-handed operation
  • Switchable marking laser and target sight

Your advantage


With the SL 5 Rinar, you can monitor pipe networks safely, efficiently, and remotely, even in inaccessible areas. This reduces effort and optimizes your processes.
With the switchable pointer laser, you can carry out the inspection without attracting attention, thus ruling out accidental damage to animals or passers-by who enter the pointer laser's range.

GasMessgeraet-4000

Technical data

Indication Illuminated LCD Display
Alarm Acoustically, optically
Sensitivity 5 ppm * m
Response time 0,2s
Gases Methane
Calibration Methane
Pointing laser Red, class 3R, can be switched off
Red dot sight Targeting device when pointing laser is switched off
Operating temperature -20° C up to 40° C
Range Up to 50 m
Protection class IP 68
Energy Supply Li Ion Battery
Operating time More than 12 hours
Casing Anodized aluminum
Dimensions 85 x 46 x 147 mm
Gewicht 450g
   